Welcome to Ningbo FXT Industrial Co.,Ltd.!
Automatic Reset Voltage Protector used in home and villa single-phase control system
  • Automatic Reset Voltage Protector used in home and villa single-phase control system

Automatic Reset Voltage Protector used in home and villa single-phase control system

Min. Order:
500 Piece/Pieces
Payment Terms:
Paypal, L/C, T/T, WU, Money Gram
Place of Origin:
Zhejiang, China (Mainland)
Means of Transport:
Ocean, Air, Land
Production Capacity:
100000pcs/week
Packing:
carton box packing
Delivery Date:
20days

  • Product Description
  • Related Products
  • Related Links
  • Automatic Reset Voltage Protector


    1. Applications
    Used in home and villa single-phase control system, when the power supply is abnormal(voltage too high or too low), cut off the power to protect electrical equipment from damage.
    2. Features 
    Built-in microprocessor, true RMS measurement, voltage measurement accuracy≤1%. 50/60Hz universal, Knob setting, LED indicator shows working status. Use (magnetic latching) relay to achieve products low-power. DIN-rail mounting.

    3. Technical parameters

    Related control supply voltage: AC220V 50Hz

    Contact configuration capacity(A): 32A, 40A,50A, 63A(80A) Resistive

    Maximum load power: 7kVA(40A), 13kVA(63A)

    Over-voltage action value: 36G: 265V 36T: 225~275V(Knob setting) 

    Over-voltage reset value: 36G: 257V 36T: Over-voltage action value*97%  

    Under-voltage action value:36G: 175V 36T: 165~215V(Knob setting)   

    Under-voltage reset value: 36G: 180V 36T:Under-voltage action value*103%

    Action delay: 36G:0.1s 36T: 0.1s~10s (Knob setting)  

    Power on delay: 36G:2s 36T: 0.3s~30s (Knob setting) 

    Reset delay: 36G: 1s 36T:0.3s~30s (Knob setting)

    Voltage measurement error: ≤1%

    Delay error: ±10%+0.1s

    Knob setting accuracy: ±1V

    Rated insulation voltage: 415V 

    Electrical durability: 100,000

    Mechanical durability: 1000,000

    Degrees of protection: IP20

    Pollution degree: III

    Altitude: ≤ 2000m

    Permissible relative humidity: ≤ 50% (40℃) No condensation

    Installation: DIN rail mounting


    4. Function diagram

    5. Wiring diagram

    6. Typical applications

    7. Dimension



    Customization is acceptable, please contact us. Thanks!